3VA2340-5JP42-0AA0 | circuit breaker 3VA2 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU550, LSI, In=400 A overload protection Ir=160 A…400 A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In neutral conductor protection adjustable (OFF, up to 100%) nut keeper kit – Siemens

SKU: 3VA2340-5JP42-0AA0

Original price was: ₹266,590.00.Current price is: ₹122,631.40. Excl. GST

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: 3VA2340-5JP42-0AA0

Same-day dispatch · GST invoice available

12 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

📋 Technical Specifications

Parameter Value
Brand Siemens
Part Number / SKU 3VA2340-5JP42-0AA0
Category MCCB
Voltage Rating 415V AC
Breaking Capacity 55 kA
Standard IEC 60947-2 / IS 13947-2
Certifications BIS certified, CE, cULus (select models)

⚡ Key Features

  • 55 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
  • Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
  • SENTRON 3VA series — optional display module shows current, voltage, and energy; add communication modules for SCADA/BMS integration without external metering.
  • Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE, cULus (select models) — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Siemens product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What does the 55 kA breaking capacity on the 3VA2340-5JP42-0AA0 mean in practice?

A: Breaking capacity (55 kA) is the maximum prospective short-circuit current the 3VA2340-5JP42-0AA0 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 55 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: What trip unit type does the 3VA2340-5JP42-0AA0 use — thermal-magnetic or electronic?

A: Refer to the product label or datasheet for the exact trip unit specification. The trip unit determines adjustability and protection accuracy.

Q: Is the 3VA2340-5JP42-0AA0 suitable for use as a motor branch circuit protector (Type E coordination)?

A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the Siemens coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.

Q: Can the 3VA2340-5JP42-0AA0 be motorised for remote switching and automation?

A: Yes. Siemens MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.

Q: After a short-circuit trip on the 3VA2340-5JP42-0AA0, can it be reset and reused immediately?

A: After a short-circuit trip, do not immediately reset the 3VA2340-5JP42-0AA0. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 55 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “3VA2340-5JP42-0AA0 | circuit breaker 3VA2 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU550, LSI, In=400 A overload protection Ir=160 A…400 A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In neutral conductor protection adjustable (OFF, up to 100%) nut keeper kit – Siemens”

Your email address will not be published. Required fields are marked *