AU RCBO 16A DP 240V AC 10kA 10mA C Curve | L&T – AUF3C201601
₹6,710.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
The AUF3C201601 AUF3C201601 is a rcbo, engineered for reliable circuit protection and isolation in demanding Indian and international installations. Key ratings include 16 A, 240V AC, 2 Poles. Buy the AU RCBO 16A DP 240V AC 10kA 10mA C Curve | L&T online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India β bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | AUF3C201601 |
| Part Number / SKU | AUF3C201601 |
| Category | RCBO |
| Current Rating | 16 A |
| Voltage Rating | 240V AC |
| Poles | 2 Poles |
| Breaking Capacity | 10 kA |
| Tripping Curve | Curve C |
| Sensitivity | 10 mA |
| Rated Voltage | 230V AC |
| Rated Frequency | 50 Hz |
| Max Break Time | β€ 300 ms at rated IΞn (per IEC 61009-1) |
| RCD Type | Type AC (sinusoidal AC sensitive) |
| Protection Functions | Overload + short-circuit + earth leakage (combined) |
| Mounting | 35mm DIN rail (EN 60715) |
| Standard | IEC 61009 / IS 12640-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 16 A current rating with combined overload + short-circuit + earth-leakage protection in one device β complete circuit protection without a separate MCB and RCCB.
- 10 mA individual earth-leakage protection β an earth fault on this circuit trips only this RCBO; other circuits in the board remain energised, unlike a shared RCCB which disconnects all.
- 10 kA short-circuit breaking capacity β full fault protection at the point of load, matching the short-circuit demand of the installation.
- 2 Poles β designed for single-phase final circuits in consumer units and small distribution boards.
- Single DIN rail module β same 17.5mm or 1P width as a standard MCB; maximises the number of protected circuits in a fixed enclosure size.
- Manufactured to IEC 61009 / IS 12640-2 β complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable β meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised AUF3C201601 product β sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders β valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available β UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the AUF3C201601 protect at its rated 16 A?
A: The AUF3C201601 is rated to carry and protect circuits up to 16 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 16 A rating is used directly. Derate by 20% for ambient temperatures above 40Β°C.
Q: What does the 10 kA breaking capacity on the AUF3C201601 mean in practice?
A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the AUF3C201601 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA β this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Why is Curve C specified for the AUF3C201601 and what loads is it optimised for?
A: Curve C on the AUF3C201601 trips magnetically at 5β10Γ rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.
Q: Why is the 10 mA sensitivity specified on the AUF3C201601 and when should you choose a different rating?
A: 10 mA is the residual current at which the AUF3C201601 will trip within 300ms. A 30mA sensitivity provides additional shock protection (mandatory for socket circuits per IS 732). 100mA is used for fire protection (no shock protection). 300mA protects feeders without nuisance tripping. Choose based on the circuit’s risk profile β never use >30mA for socket outlet circuits in wet or high-risk locations.
Q: After a short-circuit trip on the AUF3C201601, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the AUF3C201601. First, identify and clear the fault. Then inspect the device β if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 10 kA rated breaking capacity is not unlimited β it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1β3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.