DN1C MCCB 250 4P 415V AC 25kA Thermal Magnetic 50/60 Hz | L&T – CM90642OOPO
₹35,600.00 Original price was: ₹35,600.00.₹16,376.00Current price is: ₹16,376.00. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CM90642OOPO |
| Part Number / SKU | CM90642OOPO |
| Category | MCCB |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 25 kA |
| Frequency | 60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 25 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in industrial main distribution boards.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CM90642OOPO product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 25 kA breaking capacity on the CM90642OOPO mean in practice?
A: Breaking capacity (25 kA) is the maximum prospective short-circuit current the CM90642OOPO can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 25 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Is the CM90642OOPO suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM90642OOPO coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the CM90642OOPO be motorised for remote switching and automation?
A: Yes. CM90642OOPO MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the CM90642OOPO use — thermal-magnetic or electronic?
A: The CM90642OOPO uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: After a short-circuit trip on the CM90642OOPO, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the CM90642OOPO. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 25 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.