DU400N MCCB 320A 4P 415V AC 50kA Thermal Magnetic 50/60 Hz | L&T – CM98404OOQO
₹38,000.00 Original price was: ₹38,000.00.₹23,560.00Current price is: ₹23,560.00. Excl. GST
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Sourced through authorised channels, the CM98404OOQO CM98404OOQO mccb delivers dependable performance for reliable circuit protection and isolation. Key ratings include 320 A, 415V AC, 4 Poles. myelectric.in stocks the DU400N MCCB 320A 4P 415V AC 50kA Thermal Magnetic 50/60 Hz | L&T for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | CM98404OOQO |
| Part Number / SKU | CM98404OOQO |
| Category | MCCB |
| Current Rating | 320 A |
| Voltage Rating | 415V AC |
| Poles | 4 Poles |
| Breaking Capacity | 50 kA |
| Frequency | 60 Hz |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 50 kA breaking capacity at 415V AC — safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit — factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 4 Poles — three-phase + switched neutral (TN-S system) for full four-pole isolation per IEC 60364.
- Manufactured to IEC 60947-2 / IS 13947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised CM98404OOQO product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What load can the CM98404OOQO protect at its rated 320 A?
A: The CM98404OOQO is rated to carry and protect circuits up to 320 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 320 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 50 kA breaking capacity on the CM98404OOQO mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the CM98404OOQO can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Is the CM98404OOQO suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the CM98404OOQO coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the CM98404OOQO be motorised for remote switching and automation?
A: Yes. CM98404OOQO MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: What trip unit type does the CM98404OOQO use — thermal-magnetic or electronic?
A: The CM98404OOQO uses a thermal-magnetic TMD trip unit — thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.













