DZ1N MCCB 50 3P 415V AC 50kA Thermal Magnetic 50/60 Hz | L&T – DZ1T0050NXC1AOOOO
₹24,300.00 Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Looking for the DZ1N MCCB 50 3P 415V AC 50kA Thermal Magnetic 50/60 Hz | L&T? This genuine DZ1T0050NXC1AOOOO mccb is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 415V AC, 3 Poles. Order part number DZ1T0050NXC1AOOOO from myelectric.in β a trusted DZ1T0050NXC1AOOOO supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | DZ1T0050NXC1AOOOO |
| Part Number / SKU | DZ1T0050NXC1AOOOO |
| Category | MCCB |
| Voltage Rating | 415V AC |
| Poles | 3 Poles |
| Breaking Capacity | 50 kA |
| Frequency | 60 Hz |
| Rated Operational Voltage (Ue) | 415V AC (50/60 Hz) |
| Mounting | Fixed, front connected |
| Rated Frequency | 50/60 Hz |
| Standard | IEC 60947-2 / IS 13947-2 |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 50 kA breaking capacity at 415V AC β safely clears bolted three-phase faults in high-power substations and MV/LV transformer secondaries.
- Thermal-magnetic trip unit β factory-calibrated overload and short-circuit protection; suitable for standard feeder circuits without electronic adjustment.
- 3 Poles β three-phase feeder protection; neutral not switched (TN-C / IT systems).
- Manufactured to IEC 60947-2 / IS 13947-2 β complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified where applicable β meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised DZ1T0050NXC1AOOOO product β sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders β valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available β UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What does the 50 kA breaking capacity on the DZ1T0050NXC1AOOOO mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the DZ1T0050NXC1AOOOO can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA β this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: What trip unit type does the DZ1T0050NXC1AOOOO use β thermal-magnetic or electronic?
A: The DZ1T0050NXC1AOOOO uses a thermal-magnetic TMD trip unit β thermal bimetal for overload protection and electromagnetic mechanism for short-circuit. Compact, reliable, and maintenance-free for standard applications.
Q: Is the DZ1T0050NXC1AOOOO suitable for use as a motor branch circuit protector (Type E coordination)?
A: MCCBs used for motor branch circuit protection must be coordinated with the downstream overload relay for Type 2 coordination (no damage to contactor or relay on short-circuit). Verify the DZ1T0050NXC1AOOOO coordination table for the specific contactor-overload-MCCB combination to confirm Type 1 or Type 2 coordination is achieved.
Q: Can the DZ1T0050NXC1AOOOO be motorised for remote switching and automation?
A: Yes. DZ1T0050NXC1AOOOO MCCBs in this series support rotary handle adaptation and motorised operating mechanisms as accessories, enabling remote ON/OFF switching via PLC, SCADA, or BMS. Motorised MCCBs are used for automatic load management and remote trip in automated distribution systems.
Q: After a short-circuit trip on the DZ1T0050NXC1AOOOO, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the DZ1T0050NXC1AOOOO. First, identify and clear the fault. Then inspect the device β if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 50 kA rated breaking capacity is not unlimited β it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1β3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.













Reviews
Clear filtersThere are no reviews yet.