Looking for the EXORA Combo MCBs? This genuine L&T modular switch / wiring device is built for everyday wiring and control, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 16 A, 240V AC, 2 Poles. Order part number SC221616 from myelectric.in — a trusted L&T supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | L&T |
| Part Number / SKU | SC221616 |
| Category | Modular Switch / Wiring Device |
| Current Rating | 16 A |
| Voltage Rating | 240V AC |
| Poles | 2 Poles |
| Breaking Capacity | 10 kA |
| Tripping Curve | Curve C |
| Rated Frequency | 50/60 Hz |
| Standards | IS and IEC applicable standards |
| Certifications | BIS certified where applicable |
⚡ Key Features
- 16 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
- 240V AC operating voltage — compatible with standard LV distribution voltages used in Indian industrial installations.
- 10 kA short-circuit withstand or breaking capacity — protects the installation at high fault current levels.
- Manufactured to IS and IEC applicable standards — complies with Indian BIS and IEC international safety standards.
- BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised L&T product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
❓ Frequently Asked Questions
Q: What is the significance of the 16 A rating on the SC221616?
A: The 16 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: What does the 10 kA breaking capacity on the SC221616 mean in practice?
A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the SC221616 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: Why is Curve C specified for the SC221616 and what loads is it optimised for?
A: Curve C on the SC221616 trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.
Q: After a short-circuit trip on the SC221616, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the SC221616. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 10 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.