EXORA Combo MCBs – 25A DP 240V AC 10kA C Curve+16A DP 500V DC 10kA C Curve | L&T

SKU: SC222516

2,015.00 Excl. GST

Out of stock

Out of stock

14 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

The L&T SC222516 is a modular switch / wiring device, engineered for everyday wiring and control in demanding Indian and international installations. Key ratings include 25 A, 240V AC, 2 Poles. Buy the EXORA Combo MCBs online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.

📋 Technical Specifications

ParameterValue
BrandL&T
Part Number / SKUSC222516
CategoryModular Switch / Wiring Device
Current Rating25 A
Voltage Rating240V AC
Poles2 Poles
Breaking Capacity10 kA
Tripping CurveCurve C
Rated Frequency50/60 Hz
StandardsIS and IEC applicable standards
CertificationsBIS certified where applicable

⚡ Key Features

  • 25 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • 240V AC operating voltage — compatible with standard LV distribution voltages used in Indian industrial installations.
  • 10 kA short-circuit withstand or breaking capacity — protects the installation at high fault current levels.
  • Manufactured to IS and IEC applicable standards — complies with Indian BIS and IEC international safety standards.
  • BIS certified where applicable — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised L&T product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

❓ Frequently Asked Questions

Q: What is the significance of the 25 A rating on the SC222516?

A: The 25 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: What does the 10 kA breaking capacity on the SC222516 mean in practice?

A: Breaking capacity (10 kA) is the maximum prospective short-circuit current the SC222516 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 10 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Why is Curve C specified for the SC222516 and what loads is it optimised for?

A: Curve C on the SC222516 trips magnetically at 5–10× rated current, making it ideal for general-purpose circuits including fluorescent lamps, small motors, and mixed loads. Using the wrong curve can cause nuisance tripping (too sensitive) or inadequate protection (not sensitive enough). Always match the curve to the load’s inrush characteristics.

Q: After a short-circuit trip on the SC222516, can it be reset and reused immediately?

A: After a short-circuit trip, do not immediately reset the SC222516. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 10 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.

Customer Reviews