GV2RT05 | GV2 MOTOR CB HIGH INRUSH 0.63-1A TOGGLE – Schneider Electric
₹14,820.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
GVAM11 | GV2 GV3 AUX SHORT CCT C/O LHS – Schneider Electric
GVAS415 | TeSys SHUNT TRIP 415V RHS MOUNT – Schneider Electric
GVAS385 | GV2 GV3 SHUNT TRIP 415V RHS MOUNT – Schneider Electric
GVAU115 | TeSys UNDERVOLT TRIP 115V RHS MT – Schneider Electric
GVAD1001 | TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NO (fault) – Schneider Electric
GV1G02 | 3 POLES FLEXIBLE LINK – Schneider Electric
GVAN20 | TeSys GV2 & GV3 – auxiliary contact block – 2 NO – Schneider Electric
GVAU226 | TeSys UNDERVOLT 240V RHS MOUNT – Schneider Electric
GVAD1010 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NO (fault) – Schneider Electric
GVAS225 | TeSys GV2 & GV3 – shunt trip – 220…240 V AC 50 Hz – Schneider Electric
GVAS115 | GV2 GV3 SHUNT TRIP 115V RHS MOUNT – Schneider Electric
GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault) – Schneider Electric
LA9LB920 | TESYS CURRENT LIMITEUR – Schneider Electric
GVAS025 | TeSys SHUNT TRIP 24V RHS MOUNT – Schneider Electric
A9MEM1573 | PowerTag Energy F63 3P – Schneider Electric
GVAU225 | TeSys GV2 & GV3 – undervoltage trip – 220…240 V AC 50 Hz – Schneider Electric
GV2AF02 | GV2ME-LE MOUNTING PLATE – SCREW – Schneider Electric
GVAN11 | TeSys GV2 & GV3 – auxiliary contact block – 1 NO + 1 NC – Schneider Electric
GK2AF01 | MOUNTING PLATE – Schneider Electric
GVAU385 | TeSys GV2 & GV3 – undervoltage trip – 380…400V AC 50Hz – Schneider Electric
GVAD0101 | TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NC (fault) – Schneider Electric
GV2AF3 | TeSys GV2 – Combination blocks – with contactor LC1D09…D38 – Schneider Electric
GV1G09 | TeSys GV2, TeSys D & TeSys U – terminal block – 3P – from the top – Schneider Electric
GVAU415 | TeSys UNDERVOLT TRIP 415V RHS MT – Schneider Electric
Sourced through authorised channels, the Schneider Electric GV2RT05 electrical component from the TeSys Deca range delivers dependable performance for industrial, commercial, and infrastructure applications. Key ratings include 1 A, 690 V AC 50/60 Hz, 3P. myelectric.in stocks the GV2RT05 | GV2 MOTOR CB HIGH INRUSH 0.63-1A TOGGLE for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV2RT05 |
| Category | Electrical Component |
| Main | |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2RT |
| Device application | Motor protection Transformer |
| Trip unit technology | Thermal-magnetic |
| Complementary | |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 0.09 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.12 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.25 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.25 kW at 440 V AC 50/60 Hz motor protection high peak current 0.37 kW at 440 V AC 50/60 Hz motor protection high peak current 0.37 kW at 500 V AC 50/60 Hz motor protection high peak current 0.55 kW at 690 V AC 50/60 Hz motor protection high peak current 0.63 kW at 440 V AC 50/60 Hz transformer protection 0.63 kW at 500 V AC 50/60 Hz transformer protection 1 kW at 690 V AC 50/60 Hz transformer protection |
| Breaking capacity | 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Toggle |
| [In] rated current | 1 A |
| Thermal protection adjustment range | 0.63…1 A conforming to IEC 60947-2 |
| Magnetic tripping current | 22 A |
| [Ith] conventional free air thermal current | 1 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections – terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² – solid Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² – flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² – flexible with cable end |
| Tightening torque | 1.7 N.m – on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Environment | |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 |
| Product certifications | CCC UL CSA EAC LROS (Lloyds register of shipping) BV UKCA |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5…150 Hz |
| Operating altitude | <= 2000 m |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 9.300 cm |
| Package 1 Length | 8.700 cm |
| Package 1 Weight | 229.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.799 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 102.564 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 0.63–1 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the significance of the 0.63–1 A rating on the GV2RT05?
A: The 0.63–1 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.