TM100C40RN | CONTR. M100-N 40 I/O 220VAC,RELAY OUTPUT - Schneider Electric
TM100C40RN | CONTR. M100-N 40 I/O 220VAC,RELAY OUTPUT - Schneider Electric Original price was: ₹48,150.00.Current price is: ₹17,334.00. Excl. GST
Back to products
PFXSTM6B00D | Basic HMI Gateway STM6000 - Schneider Electric
PFXSTM6B00D | Basic HMI Gateway STM6000 - Schneider Electric Original price was: ₹57,845.00.Current price is: ₹23,716.45. Excl. GST

GV4LE80S | Motor Breaker GV4LE Mag 80A 100kA Elink – Schneider Electric

SKU: GV4LE80S

43,340.00 Excl. GST

Out of stock

Out of stock

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the GV4LE80S | Motor Breaker GV4LE Mag 80A 100kA Elink? This genuine Schneider Electric electrical component from the TeSys Deca range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 80 A, 690 V AC 50/60 Hz, 3P. Order part number GV4LE80S from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUGV4LE80S
CategoryElectrical Component
Main
RangeTeSys Deca
Range of productTeSys GV4
Device short nameGV4L
Product nameTeSys GV4
Product or component typeMotor circuit breaker
Device applicationMotor protection
Trip unit technologyMagnetic
Electronic
Complementary
Poles description3P
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating positionAny position
Motor power kW37 kW at 400…415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
22 kW at 400…415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
37 kW at 660…690 V AC 50/60 Hz
45 kW at 660…690 V AC 50/60 Hz
55 kW at 660…690 V AC 50/60 Hz
30 kW at 400…415 V AC 50/60 Hz
37 kW at 500 V AC 50/60 Hz
Breaking capacity120 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeToggle
[In] rated current80 A
Magnetic tripping current480…1120 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
Power dissipation per pole6.1 W
Mechanical durability40000 cycles
Electrical durability5000 cycles for AC-3 at 415 V closing
5000 cycles for AC-3 at 415 V opening
maximum operating rate25 cyc/h
Rated dutyContinuous conforming to IEC 60947-4-1
Connections – terminalsEverLink BTR screw connectors (top): 1 cable(s) 1.5…70 mm² – solid
EverLink BTR screw connectors (top): 1 cable(s) 1.5…50 mm² – flexible
EverLink BTR screw connectors (bottom): 1 cable(s) 2.5…95 mm² – solid
EverLink BTR screw connectors (bottom): 1 cable(s) 2.5…70 mm² – flexible
Tightening torque9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustnessVibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height155 mm
Width81 mm
Depth116 mm
Product weight1.5 kg
ColourGrey (RAL 7016)
Suitability for isolationYes conforming to IEC 60947-1
Environment
StandardsEN/IEC 60947-4-1
EN/IEC 60947-2
Product certificationsIEC
CCC
EAC
EU-RO MR
Climatic withstandconforming to IACS E10
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for storage-50…85 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Operating altitude5000 m
Ambient air temperature for operation-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.6 cm
Package 1 Width10.9 cm
Package 1 Length22.0 cm
Package 1 Weight1.727 kg
Unit Type of Package 2S03
Number of Units in Package 25
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight8.65 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 80 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
  • 100 kA short-circuit withstand or breaking capacity — protects the installation at high fault current levels.
  • Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

29370LV429375GV4APN01LV426937GV4APN02GV4APN04GV4ADN01GV4ADN02GV4AE11GV4AS287GV4AS137GV4AS487GV4AS027GV4AU247GV4AU027GV4AU415GV4AU137LV426920LV426940LAD96590GV4LUGA9MEM1580

❓ Frequently Asked Questions

Q: What is the significance of the 80 A rating on the GV4LE80S?

A: The 80 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.

Q: What does the 100 kA breaking capacity on the GV4LE80S mean in practice?

A: Breaking capacity (100 kA) is the maximum prospective short-circuit current the GV4LE80S can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 100 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: After a short-circuit trip on the GV4LE80S, can it be reset and reused immediately?

A: After a short-circuit trip, do not immediately reset the GV4LE80S. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 100 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.