GV4PE50N6 | MotBreak GV4PE Therm/Mag 50A 50kA lug – Schneider Electric
₹70,000.00 Original price was: ₹70,000.00.₹58,275.00Current price is: ₹58,275.00. Excl. GST
Dispatch By : 3 Weeks
Dispatch By : 3 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAD96590 | Transparent terminal shield for C Lug – Schneider Electric
GV4AU415 | COIL UVR MN 380-415V 50HZ FOR GV4 BV4 – Schneider Electric
GV4APN01 | EXTENDED ROTARY HANDLE BLACK GV4 BV4 – Schneider Electric
LV426920 | Phase barrier IEC/UL Dis and VIGI and GV – Schneider Electric
GV4AS287 | COIL ST MX 208-277V 50/60HZ FOR GV4 BV4 – Schneider Electric
LV429375 | SEALING ACCESSORIES – Schneider Electric
GV4AU137 | Coil Uvr Mn,110-130V Ac/Dc For Gv4,Bv4 – Schneider Electric
GV4AE11 | Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC – Schneider Electric
GV4AS487 | COIL ST MX 380-480V AC FOR GV4 BV4 – Schneider Electric
LV426937 | OPEN DOOR SHAFT OPERATOR NSXM PP B GV4 – Schneider Electric
LV426940 | Spreader 3P IEC Dis and GV4 – Schneider Electric
GV4ADN01 | DIRECT ROTARY HANDLE BLACK GV4 BV4 – Schneider Electric
GV4ADN02 | DIRECT ROTARY HANDLE RED GV4 BV4 – Schneider Electric
A9MEM1580 | PowerTag Energy F160 3P/3PN – Schneider Electric
GV4APN04 | EXTENDED ROTARY HANDLE IP65 RED GV4 BV4 – Schneider Electric
GV4AU027 | COIL UVR MN 24V AC/DC FOR GV4 BV4 – Schneider Electric
Looking for the GV4PE50N6 | MotBreak GV4PE Therm/Mag 50A 50kA lug? This genuine Schneider Electric electrical component from the TeSys Deca range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 50 A, 690 V AC 50/60 Hz, 3P. Order part number GV4PE50N6 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV4PE50N6 |
| Category | Electrical Component |
| Main | |
| Range | TeSys Deca |
| Range of product | TeSys GV4 |
| Device short name | GV4PE |
| Product name | TeSys GV4 |
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic Electronic |
| Complementary | |
| Poles description | 3P |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Operating position | Any position |
| Motor power kW | 11 kW at 400…415 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 660…690 V AC 50/60 Hz 15 kW at 400…415 V AC 50/60 Hz 18.5 kW at 400…415 V AC 50/60 Hz 22 kW at 400…415 V AC 50/60 Hz 18.5 kW at 500 V AC 50/60 Hz 22 kW at 500 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 22 kW at 660…690 V AC 50/60 Hz 30 kW at 660…690 V AC 50/60 Hz 37 kW at 660…690 V AC 50/60 Hz 45 kW at 660…690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947 65 kA at 240 V AC 50/60 Hz conforming to UL 60947 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947 8 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947 |
| Control type | Toggle |
| [In] rated current | 50 A |
| Magnetic tripping current | 850 A |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Power dissipation per pole | 4.6 W |
| Mechanical durability | 40000 cycles |
| Electrical durability | 5000 cycles for AC-3 at 415 V opening 5000 cycles for AC-3 at 415 V closing |
| maximum operating rate | 25 cyc/h |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Connection pitch | 27 mm without spreaders 35 mm with spreaders |
| Connections – terminals | Lugs-ring terminals |
| Tightening torque | 9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm² |
| Mechanical robustness | Vibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Height | 155 mm |
| Width | 81 mm |
| Depth | 116 mm |
| Product weight | 1.45 kg |
| Colour | Grey (RAL 7016) |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Environment | |
| Standards | CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2 |
| Product certifications | IEC UL CSA CCC EAC ATEX EU-RO MR |
| Climatic withstand | conforming to IACS E10 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Pollution degree | 3 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature for storage | -50…85 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Operating altitude | 5000 m |
| Ambient air temperature for operation | -25…70 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.000 cm |
| Package 1 Width | 22.200 cm |
| Package 1 Length | 16.700 cm |
| Package 1 Weight | 1.380 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.500 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 256 |
| Package 3 Height | 110.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 396.000 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 50 A current rating — confirmed from product specifications; size wiring and terminals to match or exceed this value.
- 50 kA short-circuit withstand or breaking capacity — protects the installation at high fault current levels.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the significance of the 50 A rating on the GV4PE50N6?
A: The 50 A rating is the device’s maximum continuous current carrying capacity under specified conditions (typically 40°C ambient). For circuit design, use 80% of this value as the design current to allow for derating due to grouping, temperature, and future load growth.
Q: What does the 50 kA breaking capacity on the GV4PE50N6 mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the GV4PE50N6 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: After a short-circuit trip on the GV4PE50N6, can it be reset and reused immediately?
A: After a short-circuit trip, do not immediately reset the GV4PE50N6. First, identify and clear the fault. Then inspect the device — if there is visible arc damage, melted insulation, or the handle does not reset smoothly, the device must be replaced. The 50 kA rated breaking capacity is not unlimited — it is the maximum fault current the device can interrupt safely for a defined number of operations (typically 1–3 at full Icu rating). After any significant fault, factor replacement into your maintenance budget.