LC1D150U7 | MAGNETIC CONTACTOR150A 440VAC3 TP 240VAC – Schneider Electric
₹70,055.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAD8N20 | Auxiliary contact block, TeSys D, 2NO, side mounting, screw clamp terminals – Schneider Electric
LA9D115603 | SET OF 2 TERMINALS BLOCK – Schneider Electric
LA5D150803 | SPARE CONTACT SET – Schneider Electric
LA4DA2U | TeSys D – suppressor module – RC circuit – 110…240 V AC – Schneider Electric
LADT0 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADR0 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
GV7AC03 | Spreader-3 pole -45 mm pitch – TeSys GV5 – Schneider Electric
LADN11 | Auxiliary contact block, TeSys D, 1NO + 1NC, front mounting, screw clamp terminals – Schneider Electric
LADN04 | Auxiliary contact block, TeSys D, 4NC, front mounting, screw clamp terminals – Schneider Electric
LX1D8M7 | TeSys D – contactor coil – LX1D8 – 220 V AC 50/60 Hz for 115 & 150 A contactor – Schneider Electric
LADR4 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LA4DFB | INTERFACE MODULE RELAY 24VDC – Schneider Electric
LADN22S | TeSys AUXILIARY CONTACT BLOCK 2NO-2NC – Schneider Electric
LADN22 | Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw clamp terminals – Schneider Electric
LAD8N11 | Auxiliary contact block, TeSys D, 1NO + 1NC, side mounting, screw clamp terminals – Schneider Electric
LADN31 | Auxiliary contact block, TeSys D, 3NO + 1NC, front mounting, screw clamp terminals – Schneider Electric
LADT4 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADN13 | Auxiliary contact block, TeSys D, 1NO + 3NC, front mounting, screw clamp terminals – Schneider Electric
LADN20 | Auxiliary contact block, TeSys D, 2NO, front mounting, screw clamp terminals – Schneider Electric
LADT2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LA4DE2U | VARISTOR SUPPRES 110-250VAC FOR D80-D115 – Schneider Electric
LA9D11502 | Mechanical and electrical interlock, TeSys D reversing & changeover, 2 contactors LC1D115-D150 – Schneider Electric
LAD8N02 | Auxiliary contact block, TeSys D, 2NC, side mounting, screw clamp terminals – Schneider Electric
LADN02 | Auxiliary contact block, TeSys D, 2NC, front mounting, screw clamp terminals – Schneider Electric
LADR2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LADN40 | Auxiliary contact block, TeSys D, 4NO, front mounting, screw clamp terminals – Schneider Electric
LADS2 | TeSys D – time delay auxiliary contact block – 1 NO + 1 NC screw clamp terminals – Schneider Electric
LA9D11569 | CONNECTION – Schneider Electric
Looking for the LC1D150U7 | MAGNETIC CONTACTOR150A 440VAC3 TP 240VAC? This genuine Schneider Electric electrical component from the TeSys range is built for industrial, commercial, and infrastructure applications, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 200 A, Power circuit: <= 1000 V AC 25...400 Hz, 3P. Order part number LC1D150U7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1D150U7 |
| Category | Electrical Component |
| Main | |
| Range | TeSys |
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-3 AC-4 AC-1 AC-3e |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage | 240 V AC 50/60 Hz |
| Complementary | |
| Motor power kW | 40 kW at 220…230 V AC 50/60 Hz (AC-3) 75 kW at 380…400 V AC 50/60 Hz (AC-3) 80 kW at 415…440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660…690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4) 40 kW at 220…230 V AC 50/60 Hz (AC-3e) 75 kW at 380…400 V AC 50/60 Hz (AC-3e) 80 kW at 415…440 V AC 50/60 Hz (AC-3e) 90 kW at 500 V AC 50/60 Hz (AC-3e) 100 kW at 660…690 V AC 50/60 Hz (AC-3e) 75 kW at 1000 V AC 50/60 Hz (AC-3e) |
| Motor power hp | 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1660 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1400 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 40 °C – 10 min for power circuit 580 A 40 °C – 1 min for power circuit 1200 A 40 °C – 10 s for power circuit 1400 A 40 °C – 1 s for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 315 A gG at <= 690 V coordination type 1 for power circuit 250 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.6 mOhm – Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1 13.5 W AC-3 13.5 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 at Ue <= 440 V 1 Mcycles 200 A AC-1 at Ue <= 440 V 0.85 Mcycles 150 A AC-3e at Ue <= 440 V |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz 1…1.15 Uc (55…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 280…350 VA 60 Hz cos phi 0.9 (at 20 °C) 280…350 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 2…18 VA 60 Hz cos phi 0.9 (at 20 °C) 2…18 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Heat dissipation | 3…4.5 W at 50/60 Hz |
| Operating time | 20…35 ms closing 40…75 ms opening |
| Maximum operating rate | 1200 cyc/h at 60 °C |
| Connections – terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end Power circuit: connector 1 10…120 mm² – cable stiffness: flexible without cable end Power circuit: connector 2 10…50 mm² – cable stiffness: flexible without cable end Power circuit: connector 1 10…120 mm² – cable stiffness: flexible with cable end Power circuit: connector 2 10…50 mm² – cable stiffness: flexible with cable end Power circuit: connector 1 10…120 mm² – cable stiffness: solid without cable end Power circuit: connector 2 10…50 mm² – cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 12 N.m – on connector hexagonal screw head 4 mm Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25…400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate Rail |
| Environment | |
| Standards | CSA C22.2 No 14 EN 60947-4-1 IEC 60947-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 |
| Product certifications | UL CCC CSA CE UKCA Marine EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
| Operating altitude | 0…3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
| Height | 158 mm |
| Width | 120 mm |
| Depth | 136 mm |
| Product weight | 2.5 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 19.000 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 21.300 cm |
| Package 1 Weight | 2.480 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 27 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 81.067 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 440V AC operating voltage — compatible with standard LV distribution voltages used in Indian industrial installations.
- Manufactured to IS/IEC 60947, IS 8828 (MCBs), IS 13947, IEC 61439 (DBs) — complies with Indian BIS and IEC international safety standards.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability: