RM17TE00 PH ROT FAILURE 208-480VAC ASYMM UV OV Schneider Electric pf153405 web
RM17TE00 | PH ROT:FAILURE 208-480VAC ASYMM UV/OV - Schneider Electric Original price was: ₹33,485.00.Current price is: ₹15,403.10. Excl. GST
Back to products
MEHVBAPP306A52 APP -BOX 3PH 30.6 kVAr 525V 50Hz Schneider Electric row 105 7
MEHVBAPP306A52 | APP -BOX 3PH 30.6 kVAr 525V 50Hz - Schneider Electric Original price was: ₹42,003.00.Current price is: ₹15,961.14. Excl. GST

LC1D65M7 | CONTACTOR 600VAC 65AMP IEC +OPTIONS – Schneider Electric

SKU: LC1D65M7

Original price was: ₹48,475.00.Current price is: ₹21,813.75. Excl. GST

Dispatch By : 3 Weeks

Dispatch By : 3 Weeks

20 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1D65M7 | CONTACTOR 600VAC 65AMP IEC +OPTIONS? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 65 A, Power circuit: <= 690 V AC 25...400 Hz, 3P. Order part number LC1D65M7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1D65M7
CategoryContactor
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-1
AC-2
AC-4
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage48 V AC 50/60 Hz
Complementary
Motor power kW30 kW at 380…400 V AC 50 Hz
37 kW at 500 V AC 50 Hz
37 kW at 660…690 V AC 50 Hz
18.5 kW at 220…230 V AC 50 Hz
30 kW at 415 V AC 50 Hz
37 kW at 1000 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3)
Motor power hp10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phases motors
20 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
50 hp at 575/600 V AC 60 Hz for 3 phases motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
3 hp at 115 V AC 60 Hz for 1 phase motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current80 A (at 60 °C) for power circuit
10 A (at 60 °C) for control circuit
Irms rated making capacity140 A at 440 V AC for control circuit conforming to IEC 60947-5-1
140 A AC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for control circuit conforming to IEC 60947-5-1
Power dissipation per pole6.4 W AC-1
4.2 W AC-3e
9.6 W AC-1
3.7 W AC-3
[Ui] rated insulation voltageControl circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified conforming to IEC 60947-1
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V CSA certified conforming to IEC 60947-1
Control circuit: 600 V CSA certified
Overvoltage categoryIII
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
Inrush power in VA160 VA cos phi 0.75 (at 20 °C)
140 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz for control circuit
Operating time12…26 ms closing
4…19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: rigid
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: rigid without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: rigid
Tightening torqueControl circuit: 1.7 N.m – on screw clamp terminal – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver pozidriv No 2
Control circuit: 1.7 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mirror contact 1 NC conforming to IEC 60947-4-1
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Terminals description ISO n°1(21-22)NC
(A1-A2)CO
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation between NC and NO contacts
1.5 ms on de-energisation between NC and NO contacts
Mounting supportPlate
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
UL 60947-4-1
IEC 60947-4-1
Product certificationsDNV
LROS (Lloyds register of shipping)
CCC
CSA
BV
UL
GL
GOST
UKCA
RINA
IP degree of protectionIP2X conforming to VDE 0106
IP2X conforming to IEC 60529
Climatic withstandconforming to IACS E10 exposure to damp heat
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessShocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor opened (10 Gn for 11 ms)
Height127 mm
Width75 mm
Depth119 mm
Product weight1.4 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.5 cm
Package 1 Width13.2 cm
Package 1 Length14.0 cm
Package 1 Weight1.447 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.566 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LA4DA1ULA4DFBLA4DT2ULA4DWBLA4DT0ULA4DT4ULADN22LADN11LADN20LAD8N11LADT2LADN40LADN31LADN02LADT0LAD8N20LADS2LADR2LADR0LADN04LADN13LADR4LADT4LAD8N02LX1D6M7

❓ Frequently Asked Questions

Q: Can multiple LC1D65M7 contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: What is the electrical and mechanical life of the LC1D65M7?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LC1D65M7 be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Q: Which Schneider Electric accessories are compatible with the LC1D65M7?

A: The Schneider Electric LC1D65M7 series supports snap-on accessories including auxiliary contact blocks, coil surge suppressors, mechanical interlocks, and direct-mount overload relays. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LC1D65M7.

Customer Reviews