GV4PE115N6 | Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, lugs terminals – Schneider Electric

SKU: GV4PE115N6

43,340.00 Excl. GST

Out of stock

Out of stock

20 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the GV4PE115N6 | Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, lugs terminals? This genuine Schneider Electric motor protection circuit breaker (mpcb) from the TeSys Deca range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 115 A, 690 V AC 50/60 Hz, 3P. Order part number GV4PE115N6 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKUGV4PE115N6
CategoryMotor Protection Circuit Breaker (MPCB)
Main
RangeTeSys Deca
Range of productTeSys GV4
Device short nameGV4PE
Product nameTeSys GV4
Product or component typeMotor circuit breaker
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Electronic
Complementary
Poles description3P
Utilisation categoryCategory A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating positionAny position
Motor power kW37 kW at 400…415 V AC 50/60 Hz
45 kW at 400…415 V AC 50/60 Hz
55 kW at 400…415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660…690 V AC 50/60 Hz
90 kW at 660…690 V AC 50/60 Hz
110 kW at 660…690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
Control typeToggle
[In] rated current115 A
Magnetic tripping current1955 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
Power dissipation per pole4.6 W
Mechanical durability40000 cycles
Electrical durability5000 cycles for AC-3 at 415 V opening
5000 cycles for AC-3 at 415 V closing
maximum operating rate25 cyc/h
Rated dutyContinuous conforming to IEC 60947-4-1
Connection pitch27 mm without spreaders
35 mm with spreaders
Connections – terminalsLugs-ring terminals
Tightening torque9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustnessVibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Phase failure sensitivityYes conforming to IEC 60947-4-1
Height155 mm
Width81 mm
Depth116 mm
Product weight1.45 kg
ColourGrey (RAL 7016)
Suitability for isolationYes conforming to IEC 60947-1
Environment
StandardsCSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
Product certificationsIEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Climatic withstandconforming to IACS E10
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for storage-50…85 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Operating altitude5000 m
Ambient air temperature for operation-25…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.500 cm
Package 1 Width10.700 cm
Package 1 Length21.600 cm
Package 1 Weight1.384 kg
Unit Type of Package 2S03
Number of Units in Package 25
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.294 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • Continuously adjustable current range 115 A — dial to the motor’s exact nameplate full-load current (FLC) for optimum overload protection without nuisance tripping.
  • 50 kA short-circuit breaking capacity — the MPCB alone handles fault interruption; no separate backup fuse required for short-circuit protection in this duty range.
  • Combined thermal and magnetic protection in one device — single MPCB replaces a separate motor-rated MCB plus thermal overload relay, saving DIN rail space and inter-device wiring.
  • Phase-loss and phase-unbalance detection — trips within seconds of a phase failure, protecting the motor from the severe overheating that single-phasing causes within minutes.
  • Manual reset only — operator must acknowledge and reset the MPCB after a trip, preventing automatic restart that could damage the motor or driven machinery.
  • Manufactured to IEC 60947-4-1 and IEC 60947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

29370LV429375GV4APN01LV426937GV4APN02GV4APN04GV4ADN01GV4ADN02GV4AE11GV4AS287GV4AS137GV4AS487GV4AS027GV4AU247GV4AU027GV4AU415GV4AU137LV426920LV426940LAD96590GV4LUGA9MEM1580

❓ Frequently Asked Questions

Q: What load can the GV4PE115N6 protect at its rated 115 A?

A: The GV4PE115N6 is rated to carry and protect circuits up to 115 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 115 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.

Q: What does the 50 kA breaking capacity on the GV4PE115N6 mean in practice?

A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the GV4PE115N6 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.

Q: Can the GV4PE115N6 replace a contactor + overload relay combination in a motor circuit?

A: The GV4PE115N6 provides motor short-circuit protection and overload protection in one device — but it cannot make/break motor current under normal operational switching (that is the contactor’s role). For motor starters requiring on/off switching, the GV4PE115N6 is used as the upstream protection device with a contactor for switching. Some MPCB series include a direct handle for manual starting of small motors without a separate contactor.

Q: What is the trip class of the GV4PE115N6 and what motor starting time does it allow?

A: MPCBs are typically rated Class 10 (trips in ≤10 seconds at 7.2× setting current), suitable for normal motors with DOL starting times up to 10 seconds. Heavy-duty motors (large fans, centrifuges, compressors) with longer starting times may need Class 20 or Class 30 protection — check the starting time against the motor’s speed-torque curve and select accordingly.

Q: Which Schneider Electric accessories are compatible with the GV4PE115N6?

A: The Schneider Electric GV4PE115N6 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the GV4PE115N6.