GV4PE80N6 | Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 50kA, thermal magnetic, lugs terminals – Schneider Electric
₹43,340.00 Excl. GST
Out of stock
Out of stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
GV4ADN01 | DIRECT ROTARY HANDLE BLACK GV4 BV4 – Schneider Electric
GV4APN04 | EXTENDED ROTARY HANDLE IP65 RED GV4 BV4 – Schneider Electric
GV4AS487 | COIL ST MX 380-480V AC FOR GV4 BV4 – Schneider Electric
GV4ADN02 | DIRECT ROTARY HANDLE RED GV4 BV4 – Schneider Electric
A9MEM1580 | PowerTag Energy F160 3P/3PN – Schneider Electric
LV429375 | SEALING ACCESSORIES – Schneider Electric
GV4AE11 | Auxiliary contact, TeSys GV4, 690VAC, 1 NO/NC – Schneider Electric
GV4AU027 | COIL UVR MN 24V AC/DC FOR GV4 BV4 – Schneider Electric
LAD96590 | Transparent terminal shield for C Lug – Schneider Electric
GV4AS287 | COIL ST MX 208-277V 50/60HZ FOR GV4 BV4 – Schneider Electric
LV426937 | OPEN DOOR SHAFT OPERATOR NSXM PP B GV4 – Schneider Electric
LV426920 | Phase barrier IEC/UL Dis and VIGI and GV – Schneider Electric
GV4APN01 | EXTENDED ROTARY HANDLE BLACK GV4 BV4 – Schneider Electric
GV4AU137 | Coil Uvr Mn,110-130V Ac/Dc For Gv4,Bv4 – Schneider Electric
LV426940 | Spreader 3P IEC Dis and GV4 – Schneider Electric
GV4AU415 | COIL UVR MN 380-415V 50HZ FOR GV4 BV4 – Schneider Electric
Looking for the GV4PE80N6 | Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 50kA, thermal magnetic, lugs terminals? This genuine Schneider Electric motor protection circuit breaker (mpcb) from the TeSys Deca range is built for reliable circuit protection and isolation, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 80 A, 690 V AC 50/60 Hz, 3P. Order part number GV4PE80N6 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV4PE80N6 |
| Category | Motor Protection Circuit Breaker (MPCB) |
| Main | |
| Range | TeSys Deca |
| Range of product | TeSys GV4 |
| Device short name | GV4PE |
| Product name | TeSys GV4 |
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic Electronic |
| Complementary | |
| Poles description | 3P |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Operating position | Any position |
| Motor power kW | 37 kW at 400…415 V AC 50/60 Hz 45 kW at 500 V AC 50/60 Hz 22 kW at 400…415 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 37 kW at 660…690 V AC 50/60 Hz 45 kW at 660…690 V AC 50/60 Hz 55 kW at 660…690 V AC 50/60 Hz 30 kW at 400…415 V AC 50/60 Hz 37 kW at 500 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947 65 kA at 240 V AC 50/60 Hz conforming to UL 60947 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947 8 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947 |
| Control type | Toggle |
| [In] rated current | 80 A |
| Magnetic tripping current | 1360 A |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Power dissipation per pole | 4.6 W |
| Mechanical durability | 40000 cycles |
| Electrical durability | 5000 cycles for AC-3 at 415 V opening 5000 cycles for AC-3 at 415 V closing |
| maximum operating rate | 25 cyc/h |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Connection pitch | 27 mm without spreaders 35 mm with spreaders |
| Connections – terminals | Lugs-ring terminals |
| Tightening torque | 9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm² |
| Mechanical robustness | Vibrations: +/- 1 mm 2…13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2…100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Height | 155 mm |
| Width | 81 mm |
| Depth | 116 mm |
| Product weight | 1.45 kg |
| Colour | Grey (RAL 7016) |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Environment | |
| Standards | CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2 |
| Product certifications | IEC UL CSA CCC EAC ATEX EU-RO MR |
| Climatic withstand | conforming to IACS E10 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Pollution degree | 3 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature for storage | -50…85 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Operating altitude | 5000 m |
| Ambient air temperature for operation | -25…70 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 16.500 cm |
| Package 1 Width | 10.900 cm |
| Package 1 Length | 22.000 cm |
| Package 1 Weight | 1.384 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.292 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Continuously adjustable current range 80 A — dial to the motor’s exact nameplate full-load current (FLC) for optimum overload protection without nuisance tripping.
- 50 kA short-circuit breaking capacity — the MPCB alone handles fault interruption; no separate backup fuse required for short-circuit protection in this duty range.
- Combined thermal and magnetic protection in one device — single MPCB replaces a separate motor-rated MCB plus thermal overload relay, saving DIN rail space and inter-device wiring.
- Phase-loss and phase-unbalance detection — trips within seconds of a phase failure, protecting the motor from the severe overheating that single-phasing causes within minutes.
- Manual reset only — operator must acknowledge and reset the MPCB after a trip, preventing automatic restart that could damage the motor or driven machinery.
- Manufactured to IEC 60947-4-1 and IEC 60947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What load can the GV4PE80N6 protect at its rated 80 A?
A: The GV4PE80N6 is rated to carry and protect circuits up to 80 A continuously. For motor loads, ensure the full-load current (FLC) of the motor does not exceed this rating. For resistive loads (heaters, lighting), the 80 A rating is used directly. Derate by 20% for ambient temperatures above 40°C.
Q: What does the 50 kA breaking capacity on the GV4PE80N6 mean in practice?
A: Breaking capacity (50 kA) is the maximum prospective short-circuit current the GV4PE80N6 can safely interrupt without damage. Before installing, verify that the prospective fault level at the installation point does not exceed 50 kA — this is checked using a fault level calculation or from the upstream transformer impedance data. Installing a breaker with insufficient breaking capacity is a serious safety violation.
Q: What is the trip class of the GV4PE80N6 and what motor starting time does it allow?
A: MPCBs are typically rated Class 10 (trips in ≤10 seconds at 7.2× setting current), suitable for normal motors with DOL starting times up to 10 seconds. Heavy-duty motors (large fans, centrifuges, compressors) with longer starting times may need Class 20 or Class 30 protection — check the starting time against the motor’s speed-torque curve and select accordingly.
Q: Can the GV4PE80N6 replace a contactor + overload relay combination in a motor circuit?
A: The GV4PE80N6 provides motor short-circuit protection and overload protection in one device — but it cannot make/break motor current under normal operational switching (that is the contactor’s role). For motor starters requiring on/off switching, the GV4PE80N6 is used as the upstream protection device with a contactor for switching. Some MPCB series include a direct handle for manual starting of small motors without a separate contactor.
Q: Which Schneider Electric accessories are compatible with the GV4PE80N6?
A: The Schneider Electric GV4PE80N6 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the GV4PE80N6.