Schneider ComPact CVS160 & CVS250 MCCB Price in Sri Lanka — Electronic Trip

The Schneider ComPact CVS MCCBs (CVS160, CVS250) are moulded case circuit breakers with Electronic Trip System (ETS) — providing current-adjustable protection with overload (Ir), short-circuit (Im), and earth fault settings. Unlike the EasyPact EZC series (fixed TM-D release), the CVS series allows site adjustment of trip thresholds. Available in 3-pole and 4-pole versions. Zero import duty to Sri Lanka under ISFTA.

ETS Electronic Trip System Explained

  • Ir (overload setting): Adjustable from 0.4× to 1.0× In. Set to motor or cable rated current for precise thermal protection.
  • Im (magnetic trip): Short-circuit instantaneous trip. Typically fixed at 10× or adjustable (ETS 2.2 allows Im adjustment).
  • Earth fault (Ig): Present on ETS 2.3 and higher — provides selective earth fault protection without RCCB.
  • ETS 2.2: Basic electronic release — Ir and Im adjustable. For most distribution and motor feeder applications.
  • ETS 6.2: Advanced release with communication-ready features and zone-selective interlocking.

CVS160 — 160A Frame MCCBs (3P & 4P)

For sub-distribution feeders and motor protection from 50A to 160A. Available in B (25kA), F (36kA) and N (50kA) breaking capacity, with TM-D fixed or ETS adjustable release.

SKUPolesRatingBreaking CapacityRelease
LV5165053P160A25kAETS 2.2
LV5165063P160A36kAETS 2.2
LV5165084P160A25kAETS 2.2
LV5164253P160AN/ASwitch-Disconnector
LV5164264P160AN/ASwitch-Disconnector
LV5165094P160A36kAETS 2.2
LV5166104P160A25kAETS 6.2
LV5166304P160A36kAETS 6.2
LV5166504P160A50kAETS 6.2
LV5164633P160A50kATM-D
LV5164674P160A50kATM-D
LV5166003P160A25kAETS 6.2
LV5166203P160A36kAETS 6.2
LV5166403P160A50kAETS 6.2
LV5164513P160A50kATM-D
LV5164623P160A50kATM-D
LV5163023P125A25kATM-D
LV5163033P160A25kATM-D
LV5163124P125A25kATM-D
LV5163134P160A25kATM-D
LV5163323P125A36kATM-D
LV5163333P160A36kATM-D
LV5163424P125A36kATM-D
LV5163434P160A36kATM-D
GFP12CT23PModuleN/AGround Fault Protection Add-on
GFP12CT24PModuleN/AGround Fault Protection Add-on

CVS250 — 250A Frame MCCBs (3P & 4P)

For main incomer protection, bus tie switches, and large motor feeders up to 250A. Higher breaking capacity and wider current range.

SKUPolesRatingBreaking CapacityRelease
LV5255073P250A50kAETS 2.2
LV5255104P250A50kAETS 2.2
LV5254253P250AN/ASwitch-Disconnector
LV5254264P250AN/ASwitch-Disconnector
LV5253224P200A25kATM-D
LV5253524P200A36kATM-D
LV5255053P250A25kAETS 2.2
LV5255063P250A36kAETS 2.2
LV5255084P250A25kAETS 2.2
LV5255094P250A36kAETS 2.2
LV5256504P250A50kAETS 6.2
LV5254584P250A50kATM-D
LV5256003P250A25kAETS 6.2
LV5256104P250A25kAETS 6.2
LV5256203P250A36kAETS 6.2
LV5256304P250A36kAETS 6.2
LV5256403P250A50kAETS 6.2
LV5254423P250A50kATM-D
LV5254523P250A50kATM-D
LV5254533P250A50kATM-D
LV5254574P250A50kATM-D
LV5253124P200A25kATM-D
LV5253134P250A25kATM-D
LV5253323P200A36kATM-D
LV5253333P250A36kATM-D
LV5253424P200A36kATM-D
LV5253434P250A36kATM-D
LV5253023P200A25kATM-D
LV5253033P250A25kATM-D

CVS vs NSX vs EZC — Quick Comparison

FeatureEasyPact EZCComPact CVSComPact NSX
Release typeFixed TM-DElectronic ETS or TM-DElectronic Micrologic
Ir adjustmentNot adjustableAdjustable 0.4–1.0×Fully programmable
Earth faultNoETS 2.3 modelsMicrologic 2.2/4.2/6.2
Breaking capacityUp to 36kAUp to 50kAUp to 150kA
PriceEconomyMid-rangePremium

📲 WhatsApp Order & Enquiry: +91 94814 00316