Schneider TeSys GV2P & GV3P Motor Circuit Breaker Price in Sri Lanka
Schneider TeSys GV2P & GV3P Motor Circuit Breaker Price in Sri Lanka
Schneider TeSys GV Motor Circuit Breakers (MCCBs with thermal-magnetic release) provide combined motor protection and switching in a single compact device. They protect against overloads (adjustable thermal release) and short circuits (fixed magnetic release) — eliminating the need for a separate overload relay. Zero import duty to Sri Lanka under ISFTA.
GV2P vs GV3P — Which to Choose?
| Feature | GV2P | GV3P |
|---|---|---|
| Current Range | 0.1A to 32A | 17A to 100A |
| Motor Range | Up to 15 kW (415V) | 7.5 kW to 45 kW (415V) |
| Breaking Capacity | 100 kA | 100 kA |
| Mounting | DIN rail / panel | Panel / fixed |
| Auxiliary contacts | Add-on modules | Add-on modules |
| Use case | Small to medium motors | Medium to large motors |
TeSys GV2P — Motor Circuit Breakers (0.1A to 32A)
The dial on each GV2P model is adjustable within the listed range. Select the model whose range covers your motor’s full-load current, then set the dial to the motor’s rated current.
| SKU | Adjustable Range | Description |
|---|---|---|
| GV2P01 | 0.1–0.16A | TeSys MOTOR CIRCUIT BREAKER |
| GV2P02 | 0.16–0.25A | TeSys MOTOR CIRCUIT BREAKER |
| GV2P03 | 0.25–0.4A | Motor circuit breaker, TeSys GV2, 3P, 0.25-0.4 A, |
| GV2P04 | 0.4–0.63A | Motor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, |
| GV2P05 | 0.63–1A | Motor circuit breaker, TeSys GV2, 3P, 0.63-1 A, th |
| GV2P06 | 1–1.6A | Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, the |
| GV2P07 | 1.6–2.5A | Motor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, t |
| GV2P08 | 2.5–4A | Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, the |
| GV2P10 | 4–6.3A | Motor circuit breaker, TeSys GV2, 3P, 4-6.3 A, the |
| GV2P14 | 6–10A | Motor circuit breaker, TeSys GV2, 3P, 6-10 A, ther |
| GV2P16 | 9–14A | Motor circuit breaker, TeSys GV2, 3P, 9-14 A, ther |
| GV2P20 | 13–18A | Motor circuit breaker, TeSys GV2, 3P, 13-18 A, the |
| GV2P21 | 17–23A | Motor circuit breaker, TeSys GV2, 3P, 17-23 A, the |
| GV2P22 | 20–25A | Motor circuit breaker, TeSys GV2, 3P, 20-25 A, the |
| GV2P32 | 24–32A | Motor circuit breaker, TeSys GV2, 3P, 24-32 A, the |
TeSys GV3P — Motor Circuit Breakers (17A to 100A)
For larger motors from 7.5 kW to 45 kW. The GV3P range handles the higher currents required for heavy-duty industrial drives.
| SKU | Adjustable Range | Description |
|---|---|---|
| GV3P32 | 23–32A | Motor circuit breaker, TeSys GV3, 3P, 23-32 A, the |
| GV3P40 | 30–40A | Motor circuit breaker, TeSys GV3, 3P, 30-40 A, the |
| GV3P50 | 37–50A | Motor circuit breaker, TeSys GV3, 3P, 37-50 A, the |
| GV3P65 | 48–65A | Motor circuit breaker, TeSys GV3, 3P, 48-65 A, the |
| GV3P73 | 62–73A | Motor circuit breaker, TeSys GV3, 3P, 62-73 A, the |
| GV3P80 | 70–80A | Motor circuit breaker, TeSys GV3, 3P, 70-80 A, the |
Motor Current to GV2P Model Selection
| Motor kW (415V 3Ph) | FLC (approx) | Recommended Model |
|---|---|---|
| 0.09 kW | 0.27A | GV2P01 (0.1–0.16A) or GV2P02 |
| 0.37 kW | 1.0A | GV2P06 (0.63–1A) |
| 0.75 kW | 1.9A | GV2P07 (1–1.6A) or GV2P08 |
| 1.5 kW | 3.7A | GV2P10 (2.5–4A) |
| 2.2 kW | 5.2A | GV2P14 (6–10A) |
| 4 kW | 9.4A | GV2P14 (6–10A) |
| 7.5 kW | 16A | GV2P20 (13–18A) |
| 11 kW | 23A | GV2P21 (17–23A) |
| 15 kW | 30A | GV2P22 (24–32A) |