GV2ME203 | TeSys SPRING TERM. MCB – Schneider Electric
₹16,505.00 Original price was: ₹16,505.00.₹7,427.25Current price is: ₹7,427.25. Excl. GST
Dispatch By : 3 Weeks
Dispatch By : 3 Weeks
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAD3B1 | TERMINAL BLOCK – Schneider Electric
LAD341 | POWER CONNECTION – Schneider Electric
LAD311 | PLATE – Schneider Electric
GVAU385 | TeSys GV2 & GV3 – undervoltage trip – 380…400V AC 50Hz – Schneider Electric
LAD324 | SPLITTER BLOCK – Schneider Electric
GVAD1001 | TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NO (fault) – Schneider Electric
GVAU225 | TeSys GV2 & GV3 – undervoltage trip – 220…240 V AC 50 Hz – Schneider Electric
GV2AF02 | GV2ME-LE MOUNTING PLATE – SCREW – Schneider Electric
GVAD1010 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NO (fault) – Schneider Electric
LAD31 | TESYS DECA MOUNTING PLATE – Schneider Electric
GVAU115 | TeSys UNDERVOLT TRIP 115V RHS MT – Schneider Electric
GVAS225 | TeSys GV2 & GV3 – shunt trip – 220…240 V AC 50 Hz – Schneider Electric
GVAS115 | GV2 GV3 SHUNT TRIP 115V RHS MOUNT – Schneider Electric
GVAS385 | GV2 GV3 SHUNT TRIP 415V RHS MOUNT – Schneider Electric
GVAX225 | TeSys SHUNT TRIP INRS 220V-50 – Schneider Electric
GVAE113 | TeSys SPRING THERM PLUG IN AUX – Schneider Electric
Sourced through authorised channels, the Schneider Electric GV2ME203 miniature circuit breaker (mcb) from the TeSys Deca range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 18 A, 690 V AC 50/60 Hz, 3P. myelectric.in stocks the GV2ME203 | TeSys SPRING TERM. MCB for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV2ME203 |
| Category | Miniature Circuit Breaker (MCB) |
| Main | |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2ME |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Complementary | |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 7.5 kW at 400/415 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Push-button |
| [In] rated current | 18 A |
| Thermal protection adjustment range | 13…18 A conforming to IEC 60947-2 |
| Magnetic tripping current | 341 A |
| [Ith] conventional free air thermal current | 18 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections – terminals | Power circuit: spring terminals 2 cable(s) 1…6 mm² – solid Power circuit: spring terminals 2 cable(s) 1.5…4 mm² – flexible without cable end Power circuit: spring terminals 2 cable(s) 1…4 mm² – flexible with cable end |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal Vertical |
| Width | 45 mm |
| Height | 101 mm |
| Depth | 78.5 mm |
| Product weight | 0.28 kg |
| Colour | Dark grey |
| Environment | |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2 |
| Product certifications | CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV RINA DNV-GL UKCA |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5…150 Hz |
| Operating altitude | <= 2000 m |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.400 cm |
| Package 1 Width | 8.600 cm |
| Package 1 Length | 11.200 cm |
| Package 1 Weight | 317.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.626 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 113.856 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Thermal-magnetic trip mechanism — bimetal element trips on sustained overload, instantaneous magnetic trip on short-circuit; two independent protection functions in one compact module.
- Manufactured to IS 8828 / IEC 60898-1 (residential) and IEC 60947-2 (industrial) — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Is the GV2ME203 suitable for both single-phase and three-phase systems?
A: The GV2ME203 with multiple poles can protect three-phase circuits. Each pole simultaneously interrupts one phase — ensuring all phases are de-energised on a fault.
Q: Can the GV2ME203 be DIN rail mounted in any standard distribution board?
A: Yes. This Schneider Electric MCB uses the standard 35mm EN 60715 DIN rail and 17.5mm module width, making it compatible with all major brand distribution boards and enclosures. Terminal capacity accommodates both rigid and flexible conductors up to the rated cross-section.
Q: What happens when the GV2ME203 trips — how do I identify and reset it?
A: When the GV2ME203 trips on fault, the handle moves to a midway position (between ON and OFF), distinctly visible from a distance. To reset: (1) identify and rectify the fault, (2) push the handle fully to OFF, (3) then switch back to ON. Never force-reset without investigating the fault cause.
Q: Which Schneider Electric accessories are compatible with the GV2ME203?
A: The Schneider Electric GV2ME203 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the GV2ME203.