LADN22P | TeSys CONTACTS BLOCK - Schneider Electric
LADN22P | TeSys CONTACTS BLOCK - Schneider Electric Original price was: ₹4,790.00.Current price is: ₹2,155.50. Excl. GST
Back to products
LP1K0610FD | 3P CONTACTOR 6A AC3 2.2KW 110VDC COIL. - Schneider Electric
LP1K0610FD | 3P CONTACTOR 6A AC3 2.2KW 110VDC COIL. - Schneider Electric Original price was: ₹5,165.00.Current price is: ₹2,324.25. Excl. GST

LP1K0601FD | 3P CONTACTOR 6A AC3 2.2KW 110VDC COIL. – Schneider Electric

SKU: LP1K0601FD

Original price was: ₹5,165.00.Current price is: ₹2,324.25. Excl. GST

Dispatch By : 11 Weeks

Dispatch By : 11 Weeks

15 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LP1K0601FD | 3P CONTACTOR 6A AC3 2.2KW 110VDC COIL.? This genuine Schneider Electric contactor from the TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 6 A, Power circuit: <= 690 V AC <= 400 Hz, 3P. Order part number LP1K0601FD from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULP1K0601FD
CategoryContactor
Main
RangeTeSys
Product or component typeContactor
Device short nameLP1K
Contactor applicationMotor control
Complementary
Utilisation categoryAC-3
AC-3e
AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit typeDC standard
[Uc] control circuit voltage110 V DC
Motor power kW1.5 kW at 220…230 V AC 50/60 Hz AC-3
2.2 kW at 380…415 V AC 50/60 Hz AC-3
3 kW at 440/690 V AC 50/60 Hz AC-3
1.5 kW at 220…230 V AC 50/60 Hz AC-3e
2.2 kW at 380…415 V AC 50/60 Hz AC-3e
3 kW at 440/690 V AC 50/60 Hz AC-3e
1.5 kW at 220…230 V AC 50/60 Hz AC-4
2.2 kW at 380…415 V AC 50/60 Hz AC-4
3 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in W3 W (at 20 °C)
Hold-in power consumption in W3 W at 20 °C
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C)
Drop-out: >= 0.10 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Coil technologyWithout built-in suppressor module
Auxiliary contacts typetype instantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Mounting supportPlate
Rail
Tightening torque0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Height58 mm
Width45 mm
Depth57 mm
Product weight0.225 kg
Environment
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.8 cm
Package 1 Width6.2 cm
Package 1 Length6.6 cm
Package 1 Weight225.0 g
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 6 A AC-3 rated — suits up to a 4 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 110V DC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LA1KN22LA1KN11LA1KN40LA1KN31LA1KN20LA1KN04LA1KN02LA1KN13LA1KN11MLA2KT2ELA4KE1FCA9MEM1573

❓ Frequently Asked Questions

Q: Is the LP1K0601FD rated 6 A for AC-3 motor duty or AC-1 resistive duty?

A: The 6 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LP1K0601FD has a coil voltage of 110V DC — what control supply is needed?

A: This Schneider Electric device requires a 110V DC control supply connected to the coil terminals (A1 and A2). For DC coils, observe polarity where marked. DC coils produce no inrush and are preferred for PLC output cards. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: Can multiple LP1K0601FD contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: What is the electrical and mechanical life of the LP1K0601FD?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LP1K0601FD be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Customer Reviews