P0718_PG | 18M Grid And 18M Cf, Pg - Schneider Electric
P0718_PG | 18M Grid And 18M Cf, Pg - Schneider Electric Original price was: ₹1,243.00.Current price is: ₹385.33. Excl. GST
Back to products
IN8401C(SZ) | ZENcelo India - 1 Module Grid and Cover frame - Silver Bronze - Schneider Electric
IN8401C(SZ) | ZENcelo India - 1 Module Grid and Cover frame - Silver Bronze - Schneider Electric Original price was: ₹1,424.00.Current price is: ₹541.12. Excl. GST

RXM4AB1P7 | MINIATURE RELAY 4C/O 230VAC – Schneider Electric

SKU: RXM4AB1P7

Original price was: ₹1,142.00.Current price is: ₹525.32. Excl. GST

Dispatch By : 1 Weeks

Dispatch By : 1 Weeks

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: RXM4AB1P7

Same-day dispatch · GST invoice available

17 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the RXM4AB1P7 | MINIATURE RELAY 4C/O 230VAC? This genuine Schneider Electric relay from the Harmony Electromechanical Relays range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 3 A at 28 V, 184…253 V AC, IP40. Order part number RXM4AB1P7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKURXM4AB1P7
CategoryRelay
Main
Range of productHarmony Electromechanical Relays
Series nameRXM series
Product or component typePlug-in relay
Relay typeMiniature relay
Contacts type and composition4 C/O
status LEDWithout
Control typeLockable test button
[Uc] control circuit voltage230 V AC 50/60 Hz
[Ithe] conventional enclosed thermal current6 A
Continuous output current5 A
Complementary
[Uimp] rated impulse withstand voltage2.5 kV during 1.2/50 µs
[Ie] rated operational current3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Minimum switching capacity170 mW at 10 mA, 17 V
Electrical durability100000 cycles for resistive load
Average coil consumption in VA1.2 at 60 Hz
Rated operational voltage limits184…253 V AC
[Ui] rated insulation voltage250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
Average consumption1.2 VA at 60 Hz
Maximum switching voltage250 V conforming to IEC
Drop-out voltage threshold>= 0.15 Uc
Load current6 A at 250 V AC
6 A at 28 V DC
Operating time20 ms
Maximum switching capacity1500 VA/168 W
Average resistance15000 Ohm at 20 °C +/- 15 %
Mechanical durability10000000 cycles
Safety reliability dataB10d = 100000
Operating rate<= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Utilisation coefficient20 %
CAD overall height79 mm
CAD overall depth78.45 mm
Reset time20 ms
Dielectric strength1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact with basic insulation
2000 V AC between poles with basic insulation
Compatibility codeRXM
Protection categoryRT I
Pollution degree2
Operating positionAny position
Test levelsLevel A group mounting
Device presentationComplete product
Contacts materialAgNi
Shape of pinFlat (faston type)
Product weight0.037 kg
Environment
Ambient air temperature for operation-40…55 °C
IP degree of protectionIP40 conforming to IEC 60529
StandardsIEC 61810-1
CSA C22.2 No 14
UL 508
Product certificationsUL
Lloyd’s
CE
CSA
GOST
IECEE CB Scheme
Ambient air temperature for storage-40…85 °C
Vibration resistance3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
Shock resistance10 gn for in operation
30 gn for not operating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.000 cm
Package 1 Width2.600 cm
Package 1 Length4.800 cm
Package 1 Weight35.000 g
Unit Type of Package 2BB1
Number of Units in Package 210
Package 2 Height3.200 cm
Package 2 Width10.300 cm
Package 2 Length12.500 cm
Package 2 Weight378.000 g
Unit Type of Package 3S02
Number of Units in Package 3240
Package 3 Height15.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight9.566 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 4 CO (Changeover) contact arrangement — all contacts independently switchable up to the contact voltage rating.
  • Manufactured to IEC 60947-5-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

RXZE2M114RXZE2M114MRXZE2S114M

❓ Frequently Asked Questions

Q: What does the 4 CO (Changeover) contact configuration on the RXM4AB1P7 mean?

A: CO (Change Over) contacts switch between two circuits — the common terminal connects to either NO or NC depending on the device state. Used for dual-purpose indication or reversing circuits.

Q: Can the RXM4AB1P7 relay be mounted on a DIN rail socket for easy replacement?

A: This Schneider Electric relay typically requires direct panel or DIN rail wiring. For applications requiring frequent relay replacement, consider the plug-in relay variant of this series with a matching socket base.

Q: How do I test the RXM4AB1P7 relay in the field without a signal source?

A: Most Schneider Electric relays can be manually forced using the test button (if fitted) — this mechanically closes the relay contacts without energising the coil, allowing functional testing of the controlled circuit. For coil testing, use a multimeter to measure coil resistance (typically 500–2000Ω for AC coils at rated voltage) and compare with datasheet values.