LC1D80AN7 | TeSys 3P EVLK CTR 80A 37KW AC3 415VAC - Schneider Electric
LC1D80AN7 | TeSys 3P EVLK CTR 80A 37KW AC3 415VAC - Schneider Electric Original price was: ₹34,950.00.Current price is: ₹15,378.00. Excl. GST
Back to products
C10N3TM016 | NSX100N 50kA AC 3P3D 16A TMD - Schneider Electric
C10N3TM016 | NSX100N 50kA AC 3P3D 16A TMD - Schneider Electric Original price was: ₹30,260.00.Current price is: ₹14,524.80. Excl. GST

LC1E95M5 | 3P CONTACTOR EasyPact TVS 45KW 400V AC3 – Schneider Electric

SKU: LC1E95M5

Original price was: ₹36,385.00.Current price is: ₹15,645.55. Excl. GST

Dispatch By : 2 Weeks

Dispatch By : 2 Weeks

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1E95M5 | 3P CONTACTOR EasyPact TVS 45KW 400V AC3? This genuine Schneider Electric contactor from the Easy TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 95 A, Power circuit: <= 690 V AC 50/60 Hz, 3P. Order part number LC1E95M5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1E95M5
CategoryContactor
Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current95 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
95 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
Motor power kW22 kW at 220/230 V AC
45 kW at 380/400 V AC
45 kW at 415/440 V AC
45 kW at 500 V AC 50/60 Hz
45 kW at 660/690 V AC
55 kW at 660…690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current120 A (at 55 °C) for power circuit
Irms rated making capacity1140 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity807.5 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current800 A 40 °C – 10 s for power circuit
400 A 40 °C – 60 s for power circuit
135 A 40 °C – 600 s for power circuit
Associated fuse rating160 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance0.8 mOhm – Ith 120 A 50 Hz for power circuit
Power dissipation per pole7.2 W AC-3
12 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability3000000 cycles
Electrical durability900000 cycles AC-3
350000 cycles AC-1
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA200 VA 50 Hz cos phi 0.75 (at 20 °C)
220 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA22 VA 60 Hz cos phi 0.3 (at 20 °C)
20 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20…35 ms on closing
6…30 ms on opening
Maximum operating rate1200 cyc/h 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 4…16 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 4…25 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 4…25 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 4…50 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 12 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for auxiliary contact circuit
Minimum switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportDIN rail
Plate
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.1
GB/T 14048.4
GB/T 14048.5
EN/IEC 60335-1:Clause 30.2
EN/IEC 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
CE
EAC
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height127 mm
Width85 mm
Depth121 mm
Product weight1.52 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.000 cm
Package 1 Width15.000 cm
Package 1 Length15.500 cm
Package 1 Weight1.535 kg
Unit Type of Package 2S03
Number of Units in Package 25
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.178 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAERCULAEM4LAEN22LAEN11LAEN20LAEN02LAETSD

❓ Frequently Asked Questions

Q: Can multiple LC1E95M5 contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: What is the electrical and mechanical life of the LC1E95M5?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Q: Can the LC1E95M5 be used for reversing duty (forward/reverse motor control)?

A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.

Q: Which Schneider Electric accessories are compatible with the LC1E95M5?

A: The Schneider Electric LC1E95M5 series supports snap-on accessories including auxiliary contact blocks, coil surge suppressors, mechanical interlocks, and direct-mount overload relays. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the LC1E95M5.