Schneider EasyPact TVS LRE Thermal Overload Relay Price in Sri Lanka

The Schneider EasyPact TVS LRE thermal overload relay provides motor overload protection by tripping when motor current exceeds the set dial value for a sustained period. Designed to mount directly on the LC1E contactor (plug-in mounting), the LRE uses a bimetal strip with adjustable trip current. Available in ranges covering 0.16A to 630A. Zero import duty to Sri Lanka under ISFTA.

How to Select an LRE Overload Relay

  • Trip range: Select the model whose adjustment range covers the motor’s full-load current (FLC). Set the dial to the motor’s nameplate ampere value.
  • Trip class: LRE standard is Class 10 (trips within 10 seconds at 7.2× FLC). Class 20 models available for high-inertia loads.
  • Manual vs auto reset: Manual reset (requires operator action after trip) is preferred for safety. Auto reset available for unmanned pump applications.
  • Mounting: Mounts directly on LC1E contactor — no wiring needed. Also panel-mount with adapter.

LRE — Small Range (0.16A to 10A)

For small motors up to approximately 4 kW (415V).

SKUTrip RangeDescription
LRE010.1–0.16AThermal Overload Relay – 0.1–0.16A
LRE020.16–0.25AThermal Overload Relay – 0.16–0.25A
LRE030.25–0.4ADifferential Thermal Overload Relay (Class 10A) – 0.25–0.4A
LRE040.4–0.63ADifferential Thermal Overload Relay (Class 10A) – 0.4–0.63A
LRE050.63–1ADifferential Thermal Overload Relay (Class 10A) – 0.63–1A
LRE061–1.6ADifferential Thermal Overload Relay (Class 10A) – 1–1.6A
LRE071.6–2.5ADifferential Thermal Overload Relay (Class 10A) – 1.6–2.5A
LRE082.5–4ADifferential Thermal Overload Relay (Class 10A) – 2.5–4A
LRE104–6ADifferential Thermal Overload Relay (Class 10A) – 4–6A
LRE125.5–8ADifferential Thermal Overload Relay (Class 10A) – 5.5–8A
LRE147–10ADifferential Thermal Overload Relay (Class 10A) – 7–10A
LRE169–13ADifferential Thermal Overload Relay (Class 10A) – 9–13A
LRE2112–18ADifferential Thermal Overload Relay (Class 10A) – 12–18A
LRE2216–24ADifferential Thermal Overload Relay (Class 10A) – 16–24A
LRE32217–25ADifferential Thermal Overload Relay (Class 10A) – 17–25A

LRE — Medium Range (23A to 135A)

For motors from 11 kW to 55 kW. Includes both standard and differential class 10A models.

SKUTrip RangeDescription
LRE3223–32ADifferential Thermal Overload Relay (Class 10A) – 23–32A
LRE35323–32ADifferential Thermal Overload Relay (Class 10A) – 23–32A
LRE3530–38ADifferential Thermal Overload Relay (Class 10A) – 30–38A
LRE35530–40ADifferential Thermal Overload Relay (Class 10A) – 30–40A
LRE35737–50ADifferential Thermal Overload Relay (Class 10A) – 37–50A
LRE35948–65ADifferential Thermal Overload Relay (Class 10A) – 48–65A
LRE36155–70ADifferential Thermal Overload Relay (Class 10A) – 55–70A
LRE36363–80ADifferential Thermal Overload Relay (Class 10A) – 63–80A
LRE36580–104ADifferential Thermal Overload Relay (Class 10A) – 80–104A
LRE48051–81AThermal Overload Relay – 51–81A
LRE48162–99ADifferential Thermal Overload Relay (Class 10A) – 62–99A
LRE48284–135ADifferential Thermal Overload Relay (Class 10A) – 84–135A

LRE — Large Range (124A to 630A)

For large motors from 55 kW to 315 kW.

SKUTrip RangeDescription
LRE483124–198ADifferential Thermal Overload Relay (Class 10A) – 124–198A
LRE484146–234ADifferential Thermal Overload Relay (Class 10A) – 146–234A
LRE485174–279AThermal Overload Relay – 174–279A
LRE486208–333AThermal Overload Relay – 208–333A
LRE487258–414AThermal Overload Relay – 258–414A
LRE488321–513AThermal Overload Relay – 321–513A
LRE489394–630AThermal Overload Relay – 394–630A

LRE Accessories

Terminal blocks for panel wiring compatibility.

SKUDescription
LAEB1EasyPact TVS Terminal Block – for LRE01…LRE35
LAEB3EasyPact TVS Terminal Block – for LRE322…LRE365

📲 WhatsApp Order & Enquiry: +91 94814 00316