LAD6K10M | CONTACTOR MECH. LATCH CONTACT BLOCK IEC – Schneider Electric
₹13,065.00 Original price was: ₹13,065.00.₹5,879.25Current price is: ₹5,879.25. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
CAD50P7 | TeSys AUXILIARY CONTACTOR – Schneider Electric
CAD32M7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 220 V AC standard coil - Schneider Electric
CAD32G7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 120 V AC standard coil - Schneider Electric
CAD323BD | CAD323BD Contactor 32A 3P 24VDC Coil | Schneider Electric – Schneider Electric
CAD32E7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 48 V AC standard coil - Schneider Electric
CAD50E7 | TeSys D control relay – 5 NO – <= 690 V - 48 V AC standard coil - Schneider Electric
CAD32V7 | TeSys AUXILIARY CONTACTOR – Schneider Electric
CAD32P7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 230 V AC standard coil - Schneider Electric
CAD32F7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 110 V AC standard coil - Schneider Electric
CAD503BD | TeSys AUXILIARY CONTACTOR – Schneider Electric
CAD32B7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 24 V AC standard coil - Schneider Electric
CAD50M7 | TeSys D control relay – 5 NO – <= 690 V - 220 V AC standard coil - Schneider Electric
CAD32MD | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 220 V DC standard coil - Schneider Electric
CAD50F7 | TeSys D control relay – 5 NO – <= 690 V - 110 V AC standard coil - Schneider Electric
CAD32BD | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 24 V DC standard coil - Schneider Electric
CAD32U7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 240 V AC standard coil - Schneider Electric
CAD323E7 | TeSys AUXILIARY CONTACTOR – Schneider Electric
CAD32GD | TeSys AUXILIARY CONTACTOR – Schneider Electric
CAD32FD | TeSys D control relay – 3 NO + 2 NC – <= 690 V - 110 V DC standard coil - Schneider Electric
CAD50BD | TeSys D control relay – 5 NO – <= 690 V - 24 V DC standard coil - Schneider Electric
The Schneider Electric LAD6K10M is a contactor from the TeSys range, engineered for motor control and switching in demanding Indian and international installations. Key ratings include IP2X. Buy the LAD6K10M | CONTACTOR MECH. LATCH CONTACT BLOCK IEC online at myelectric.in with GST invoice, genuine-product assurance, and fast delivery across India — bulk and worldwide export enquiries welcome.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LAD6K10M |
| Category | Contactor |
| Main | |
| Range | TeSys |
| Product or component type | Mechanical latch block |
| Product compatibility | LC1D09…D38 AC/DC LC1DT20…DT40 AC/DC LC1D40A…D80A 3 phases AC/DC LC1DT60A 3 phases + neutral AC/DC LC1DT80A 3 phases + neutral AC/DC |
| [Uc] control circuit voltage | 220/240 V AC 50/60 Hz 220/240 V DC |
| Complementary | |
| Mounting location | Front side |
| Tripping control | Electrical Manual |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Power required in VA | 25 for AC circuit |
| Power required in W | 30 W for DC circuit |
| Mechanical durability | 500000 cycles |
| Maximum operating rate | 1200 cyc/h |
| On-load factor | 10 % |
| Product weight | 0.07 kg |
| Environment | |
| Product certifications | UL CSA |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…55 °C |
| Ambient air temperature for storage | -40…80 °C |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.500 cm |
| Package 1 Width | 5.000 cm |
| Package 1 Length | 6.500 cm |
| Package 1 Weight | 98.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 32 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 3.270 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 1024 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 112.640 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: What is the electrical and mechanical life of the LAD6K10M?
A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.
Q: Can the LAD6K10M be used for reversing duty (forward/reverse motor control)?
A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.
Q: Can multiple LAD6K10M contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.