LC1E3210M7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 32A - 220 V AC coil - Schneider Electric
₹9,045.00 Original price was: ₹9,045.00.₹3,618.00Current price is: ₹3,618.00. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
LAEN11 | EasyPact TVS – auxiliary contact block – 1 NO + 1 NC – screw-clamps terminals – Schneider Electric
LAETSD | EasyPact TVS – time delay – on delay – 1 NO + 1 NC – Schneider Electric
LAEN02 | EasyPact TVS – auxiliary contact block – 2 NC – screw-clamps terminals – Schneider Electric
LAEM1 | EasyPact TVS – mechanical interlock – for LC1E06…E65 – Schneider Electric
LAERCU | RC SURGE BLOCK 110 240 VAC EasyPact TVS – Schneider Electric
LAEN22 | EasyPact TVS – auxiliary contact block – 2 NO + 2 NC – screw-clamps terminals – Schneider Electric
LAEN20 | EasyPact TVS – auxiliary contact block – 2 NO – screw-clamps terminals – Schneider Electric
Looking for the LC1E3210M7 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 32A - 220 V AC coil? This genuine Schneider Electric contactor from the Easy TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 32 A, Power circuit: <= 690 V AC 50/60 Hz, 3P. Order part number LC1E3210M7 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | LC1E3210M7 |
| Category | Contactor |
| Main | |
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 32 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Complementary | |
| Motor power kW | 7.5 kW at 220/230 V AC 50/60 Hz 15 kW at 380/400 V AC 15 kW at 415/440 V AC 15 kW at 500 V AC 15 kW at 660/690 V AC 18.5 kW at 660…690 V |
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 50 A (at 55 °C) for power circuit |
| Irms rated making capacity | 416 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 272 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C – 10 s for power circuit 138 A 40 °C – 60 s for power circuit 60 A 40 °C – 600 s for power circuit |
| Associated fuse rating | 63 A gG at <= 690 V coordination type 1 for power circuit 10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1 |
| Average impedance | 2.5 mOhm – Ith 50 A 50 Hz for power circuit |
| Power dissipation per pole | 2 W AC-3 5 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 8000000 cycles |
| Electrical durability | 1000000 cycles AC-3 350000 cycles AC-1 |
| Control circuit type | AC at 50/60 Hz |
| Control circuit voltage limits | 0.85…1.1 Uc (-5…55 °C):operational 50/60 Hz 0.3…0.6 Uc (-5…55 °C):drop-out 50/60 Hz |
| Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W for control circuit |
| Operating time | 12…22 ms on closing 4…19 ms on opening |
| Maximum operating rate | 1800 cyc/h 60 °C |
| Connections – terminals | Power circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m |
| Auxiliary contact composition | 1 NO |
| Minimum switching voltage | 17 V for auxiliary contact circuit |
| Minimum switching current | 5 mA for auxiliary contact circuit |
| Insulation resistance | > 10 MOhm for auxiliary contact circuit |
| Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| Mounting support | DIN rail Plate |
| Environment | |
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ IS/IEC 60947-1 IS/IEC 60947-4-1 IS/IEC 60947-5-1 |
| Product certifications | CB Scheme CCC CE EAC BIS |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
| Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5…300 Hz) Vibrations contactor closed (3 Gn, 5…300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
| Height | 84 mm |
| Width | 56 mm |
| Depth | 86 mm |
| Product weight | 0.45 kg |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.700 cm |
| Package 1 Width | 8.500 cm |
| Package 1 Length | 9.000 cm |
| Package 1 Weight | 441.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.134 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- 32 A AC-3 rated — suits up to a 15 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
- 220V AC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
- 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
- Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
- Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: Is the LC1E3210M7 rated 32 A for AC-3 motor duty or AC-1 resistive duty?
A: The 32 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.
Q: The LC1E3210M7 has a coil voltage of 220V AC — what control supply is needed?
A: This Schneider Electric device requires a 220V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.
Q: What circuit can the 3 NO (Normally Open) contacts of the LC1E3210M7 switch at 440V AC?
A: The 3 NO (Normally Open) contacts on the LC1E3210M7 are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.
Q: Can the LC1E3210M7 be used for reversing duty (forward/reverse motor control)?
A: Contactors used for reversing must be wired with two contactors interlocked so only one can energise at a time. The Schneider Electric series provides mechanical interlock kits that physically prevent both contactors from closing simultaneously — mandatory for reversing and brake applications to prevent phase-to-phase short circuits.
Q: Can multiple LC1E3210M7 contactors be wired for star-delta starting?
A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.