LC1E3801E5 Easy TeSys contactor 3P 3 NO AC-3 cpb100418 1500x1500
LC1E3210M7 | Easy TeSys contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 220 V AC coil - Schneider Electric Original price was: ₹9,045.00.Current price is: ₹3,618.00. Excl. GST
Back to products
LC1E3210U5 Easy TeSys contactor 3P 3 NO AC-3 lc1e3210u5 image 1500x1500
LC1E3210U5 | Easy TeSys contactor 3P(3 NO) - AC-3 - <= 440 V 32A - 240 V AC coil - Schneider Electric Original price was: ₹9,190.00.Current price is: ₹3,951.70. Excl. GST

LC1E3210N5 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 32A - 415 V AC coil - Schneider Electric

SKU: LC1E3210N5

Original price was: ₹9,045.00.Current price is: ₹3,618.00. Excl. GST

In stock

In stock

My Electric Support Online · Mon–Sat 9am–6pm IST
Product enquiry
Order on WhatsApp SKU: LC1E3210N5

Same-day dispatch · GST invoice available

19 People watching this product now!

Order protection

Buy with complete confidence.

We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.

Buyer protection on every order
Global DeliveryShipped pan-India and to export markets.
On-Time DeliveryPacked and dispatched on schedule.
100% OriginalFrom brand-authorised channels only.
GST InvoiceCompliant, ITC-ready tax invoice.
Secure PaymentEncrypted, trusted payment gateways.
Also included Dedicated account manager Technical support Bulk & business pricing 3-day replacement

Looking for the LC1E3210N5 | Easy TeSys contactor 3P(3 NO) – AC-3 – <= 440 V 32A - 415 V AC coil? This genuine Schneider Electric contactor from the Easy TeSys range is built for motor control and switching, combining proven reliability with full compliance to applicable IEC/IS standards. Key ratings include 32 A, Power circuit: <= 690 V AC 50/60 Hz, 3P. Order part number LC1E3210N5 from myelectric.in — a trusted Schneider Electric supplier offering competitive pricing, GST billing, and shipping across India and overseas.

📋 Technical Specifications

Product
BrandSchneider Electric
Part Number / SKULC1E3210N5
CategoryContactor
Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current32 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage415 V AC 50 Hz
Complementary
Motor power kW7.5 kW at 220/230 V AC 50/60 Hz
15 kW at 380/400 V AC 50/60 Hz
15 kW at 415/440 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660/690 V AC 50/60 Hz
18.5 kW at 660…690 V AC 50/60 Hz
Pole contact composition3 NO
[Ith] conventional free air thermal current50 A (at 55 °C) for power circuit
Irms rated making capacity416 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity272 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current260 A 40 °C – 10 s for power circuit
138 A 40 °C – 60 s for power circuit
60 A 40 °C – 600 s for power circuit
Associated fuse rating63 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance2.5 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole2 W AC-3
5 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability8000000 cycles
Electrical durability1000000 cycles AC-3
350000 cycles AC-1
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing
4…19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections – terminalsPower circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 2.1 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for auxiliary contact circuit
Minimum switching current5 mA for auxiliary contact circuit
Insulation resistance> 10 MOhm for auxiliary contact circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportDIN rail
Plate
Environment
StandardsEN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.1
GB/T 14048.4
GB/T 14048.5
EN/IEC 60335-1:Clause 30.2
EN/IEC 60335-2-40:Annex JJ
IS/IEC 60947-1
IS/IEC 60947-4-1
IS/IEC 60947-5-1
Product certificationsCB Scheme
CCC
CE
EAC
BIS
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height84 mm
Width56 mm
Depth86 mm
Product weight0.45 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.800 cm
Package 1 Width8.700 cm
Package 1 Length9.200 cm
Package 1 Weight449.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight11.294 kg
Contractual warranty
Warranty (in months)18

⚡ Key Features

  • 32 A AC-3 rated — suits up to a 15 kW squirrel-cage induction motor at 415V for direct-on-line (DOL) starting and running.
  • 415V AC coil — connects directly to pushbutton station, PLC digital output, or timer relay; suitable for standard 50Hz Indian industrial control circuits.
  • 3 Poles main contacts with silver-alloy (AgSnO₂) tips — rated for AC-3 duty (DOL motor starting/stopping); low contact resistance reduces heat at rated current.
  • Main contacts rated up to 440V AC — compatible with 415V AC three-phase Indian supply and 480V AC North American systems.
  • Manufactured to IEC 60947-4-1 / IS 13947-4-1 — complies with the applicable Indian BIS and IEC international standards for this product category.
  • BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
  • Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
  • GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
  • Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.

🔗 Compatible Products & Accessories

The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:

LAERCNLAEM1LAEN22LAEN11LAEN20LAEN02LAETSD

❓ Frequently Asked Questions

Q: Is the LC1E3210N5 rated 32 A for AC-3 motor duty or AC-1 resistive duty?

A: The 32 A rating of this Schneider Electric contactor applies to AC-3 duty (squirrel cage motor starting and running). For AC-1 (resistive/non-inductive) loads, the current can be up to ~1.3× the AC-3 rating. AC-4 (plugging/reversing) requires significant de-rating — consult the Schneider Electric selection table.

Q: The LC1E3210N5 has a coil voltage of 415V AC — what control supply is needed?

A: This Schneider Electric device requires a 415V AC control supply connected to the coil terminals (A1 and A2). For AC coils, ensure the control circuit voltage is stable — voltage drops below 85% of rated coil voltage can cause chatter and coil overheating. Always fit a surge suppressor across the coil when switching with a PLC or solid-state relay.

Q: What circuit can the 3 NO (Normally Open) contacts of the LC1E3210N5 switch at 440V AC?

A: The 3 NO (Normally Open) contacts on the LC1E3210N5 are rated for switching at up to 440V AC. These auxiliary contacts are typically used for: (1) indication lamps and buzzers, (2) PLC input feedback to confirm device state, (3) interlocking with other contactors or relays in control circuits. Check the current rating of the auxiliary contact (typically 10A at 250V AC) — do not use for power load switching.

Q: Can multiple LC1E3210N5 contactors be wired for star-delta starting?

A: Yes. Star-delta starters use three contactors: main (KM1), star (KM2), and delta (KM3). The Schneider Electric contactor series supports mechanical and electrical interlocking accessories that prevent simultaneous energisation of star and delta contactors — critical for safety. Ensure all three contactors are rated correctly for the motor FLC and star-delta transition current.

Q: What is the electrical and mechanical life of the LC1E3210N5?

A: Schneider Electric contactors are rated for millions of operations: typically 10–30 million mechanical operations and 1–3 million electrical operations at rated current and voltage (AC-3 duty). High-frequency switching applications (>10 operations/hour) require checking the specific thermal capacity of the contactor for continuous duty without overheating.

Customer Reviews