GV2ME07 | Motor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, thermal magnetic, screw clamp terminals – Schneider Electric
₹10,630.00 Original price was: ₹10,630.00.₹4,464.60Current price is: ₹4,464.60. Excl. GST
In stock
In stock
Order protection
Buy with complete confidence.
We back each order with genuine supply, on-time dispatch and GST or commercial invoicing as required.
Additional Addons/Accessories
GV1L3 | GV2ME-GV2P CURRENT LIMITING – Schneider Electric
GV1G09 | TeSys GV2, TeSys D & TeSys U – terminal block – 3P – from the top – Schneider Electric
GV2AF4 | TERMINAL BLOCK – Schneider Electric
GV2G254 | Linergy FT – Comb busbar – 63 A – 2 tap-offs – 54 mm pitch – Schneider Electric
GV1G02 | 3 POLES FLEXIBLE LINK – Schneider Electric
GV2G05 | TeSys GV2, TeSys D & TeSys U – terminal block – 3P – for GV1L3 – Schneider Electric
GV2G472 | 4 TAP OFFS BUSBAR GV2 63A 72MM PITCH – Schneider Electric
GVAM11 | GV2 GV3 AUX SHORT CCT C/O LHS – Schneider Electric
GVAE20 | TeSys GV2 & GV3 – auxiliary contact – 2 NO – Schneider Electric
GV2AF02 | GV2ME-LE MOUNTING PLATE – SCREW – Schneider Electric
GVAX225 | TeSys SHUNT TRIP INRS 220V-50 – Schneider Electric
GVAD1010 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NO (fault) – Schneider Electric
GVAU225 | TeSys GV2 & GV3 – undervoltage trip – 220…240 V AC 50 Hz – Schneider Electric
GVAN11 | TeSys GV2 & GV3 – auxiliary contact block – 1 NO + 1 NC – Schneider Electric
GVAE1 | TeSys GV2 & GV3 – auxiliary contact – 1 NO/NC – Schneider Electric
GVAU226 | TeSys UNDERVOLT 240V RHS MOUNT – Schneider Electric
GVAS025 | TeSys SHUNT TRIP 24V RHS MOUNT – Schneider Electric
GV2G454 | Linergy FT – Comb busbar – 63 A – 4 tap-offs – 54 mm pitch – Schneider Electric
GVAU385 | TeSys GV2 & GV3 – undervoltage trip – 380…400V AC 50Hz – Schneider Electric
LAD311 | PLATE – Schneider Electric
LAD31 | TESYS DECA MOUNTING PLATE – Schneider Electric
GV2AF3 | TeSys GV2 – Combination blocks – with contactor LC1D09…D38 – Schneider Electric
A9MEM1573 | PowerTag Energy F63 3P – Schneider Electric
GVAD0101 | TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NC (fault) – Schneider Electric
GVAU415 | TeSys UNDERVOLT TRIP 415V RHS MT – Schneider Electric
GVAD1001 | TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NO (fault) – Schneider Electric
GV2G345 | 3 TAP OFFS BUSBAR GV2 63A 45MM PITCH – Schneider Electric
GV2G245 | 2 TAP OFFS BUSBAR GV2 63A 45MM PITCH – Schneider Electric
GVAS115 | GV2 GV3 SHUNT TRIP 115V RHS MOUNT – Schneider Electric
GVAX415 | TeSys SHUNT TRIP INRS 415V-50 – Schneider Electric
GVAN20 | TeSys GV2 & GV3 – auxiliary contact block – 2 NO – Schneider Electric
LA9LB920 | TESYS CURRENT LIMITEUR – Schneider Electric
GK2AF01 | MOUNTING PLATE – Schneider Electric
GVAE11 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC – Schneider Electric
GVAD0110 | TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC (fault) – Schneider Electric
GVAS225 | TeSys GV2 & GV3 – shunt trip – 220…240 V AC 50 Hz – Schneider Electric
GV2G445 | Linergy FT – Comb busbar – 63 A – 4 tap-offs – 45 mm pitch – Schneider Electric
GV2G554 | Linergy FT – Comb busbar – 63 A – 5 tap-offs – 54 mm pitch – Schneider Electric
GVAS385 | GV2 GV3 SHUNT TRIP 415V RHS MOUNT – Schneider Electric
GV2G354 | Linergy FT – Comb busbar – 63 A – 3 tap-offs – 54 mm pitch – Schneider Electric
Sourced through authorised channels, the Schneider Electric GV2ME07 motor protection circuit breaker (mpcb) from the TeSys Deca range delivers dependable performance for reliable circuit protection and isolation. Key ratings include 2.5 A, 690 V AC 50/60 Hz, 3P. myelectric.in stocks the GV2ME07 | Motor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, thermal magnetic, screw clamp terminals for contractors, panel builders, and project buyers — buy online with GST invoice, or request a bulk quote for domestic supply and export to UAE, Singapore, UK, USA, Sri Lanka and more.
📋 Technical Specifications
| Product | |
| Brand | Schneider Electric |
| Part Number / SKU | GV2ME07 |
| Category | Motor Protection Circuit Breaker (MPCB) |
| Main | |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2ME |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Complementary | |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 0.75 kW at 400/415 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.5 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Push-button |
| [In] rated current | 2.5 A |
| Thermal protection adjustment range | 1.6…2.5 A conforming to IEC 60947-2 |
| Magnetic tripping current | 39 A |
| [Ith] conventional free air thermal current | 2.5 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections – terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² – solid Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² – flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² – flexible with cable end |
| Tightening torque | 1.7 N.m – on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Product weight | 0.26 kg |
| Colour | Dark grey |
| Environment | |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2 |
| Product certifications | CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV RINA DNV-GL UKCA |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5…150 Hz |
| Operating altitude | <= 2000 m |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 8.600 cm |
| Package 1 Length | 9.400 cm |
| Package 1 Weight | 257.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.450 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 109.488 kg |
| Contractual warranty | |
| Warranty (in months) | 18 |
⚡ Key Features
- Continuously adjustable current range 1.6–2.5 A — dial to the motor’s exact nameplate full-load current (FLC) for optimum overload protection without nuisance tripping.
- TeSys GV2 series — direct mounting on LC1 contactors via clip adapter; forms a self-contained DOL starter in the smallest possible panel footprint.
- Combined thermal and magnetic protection in one device — single MPCB replaces a separate motor-rated MCB plus thermal overload relay, saving DIN rail space and inter-device wiring.
- Phase-loss and phase-unbalance detection — trips within seconds of a phase failure, protecting the motor from the severe overheating that single-phasing causes within minutes.
- Manual reset only — operator must acknowledge and reset the MPCB after a trip, preventing automatic restart that could damage the motor or driven machinery.
- Manufactured to IEC 60947-4-1 and IEC 60947-2 — complies with the applicable Indian BIS and IEC international standards for this product category.
- BIS certified, CE marked, RoHS compliant — meets Indian regulatory requirements for use in government, commercial, and industrial electrical installations.
- Genuine authorised Schneider Electric product — sourced directly from the official distribution network with full manufacturer traceability and warranty.
- GST invoice provided for India orders — valid for corporate procurement, government project orders, and public tender supply via myelectric.in.
- Worldwide export available — UAE, Singapore, UK, USA, Sri Lanka & more. Contact +91 94814 00316 for bulk pricing and international shipping.
🔗 Compatible Products & Accessories
The following genuine accessories and compatible devices are designed to work with this product. Contact myelectric.in for pricing and availability:
❓ Frequently Asked Questions
Q: How do I set the 1.6–2.5 A adjustable range on the GV2ME07 for my motor?
A: Turn the setting dial to the motor’s nameplate full-load current (FLC) — the FLC must fall within the 1.6–2.5 A range of this device. Setting it at the motor FLC (not the maximum of the range) gives correct overload trip timing while still riding through normal starting inrush. If the motor FLC is outside this range, select the adjacent rating in the same series.
Q: Can the GV2ME07 replace a contactor + overload relay combination in a motor circuit?
A: The GV2ME07 provides motor short-circuit protection and overload protection in one device — but it cannot make/break motor current under normal operational switching (that is the contactor’s role). For motor starters requiring on/off switching, the GV2ME07 is used as the upstream protection device with a contactor for switching. Some MPCB series include a direct handle for manual starting of small motors without a separate contactor.
Q: What is the trip class of the GV2ME07 and what motor starting time does it allow?
A: MPCBs are typically rated Class 10 (trips in ≤10 seconds at 7.2× setting current), suitable for normal motors with DOL starting times up to 10 seconds. Heavy-duty motors (large fans, centrifuges, compressors) with longer starting times may need Class 20 or Class 30 protection — check the starting time against the motor’s speed-torque curve and select accordingly.
Q: Which Schneider Electric accessories are compatible with the GV2ME07?
A: The Schneider Electric GV2ME07 series supports snap-on accessories including auxiliary contacts (OF), alarm contacts (SD), shunt trip coils (MX), undervoltage releases (MN), and comb busbars. Accessories are series-specific — always verify compatibility using the Schneider Electric product catalogue before ordering. myelectric.in can advise on the correct accessory part numbers for the GV2ME07.
Q: What is the difference between a Motor Protection Circuit Breaker (MPCB) and a standard MCB — and why use the GV2ME07?
A: A standard MCB protects against overload and short-circuit only. A Motor Protection Circuit Breaker (MPCB) adds adjustable thermal overload matched to motor FLC, Class 10/20 trip curves for motor starting inrush, and phase-loss sensitivity — making it the correct device for motor branch circuits where a standard MCB would either nuisance-trip on motor starting or fail to protect adequately against slow overloads. Choose the GV2ME07 when the application specifically requires motor protection circuit breaker (mpcb) characteristics.